A basic solar-energy scenario multiplies array capacity in kW by equivalent peak-sun hours, days and a chosen performance fraction. A 5 kW array with four peak-sun hours per day, an 80% factor and 30 days gives 480 kWh. This is a supplied-assumption estimate, not a location-specific yield prediction.

Your numbers

BROWSER-LOCAL INPUTS

Your inputs stay in this browser. No account needed.

RESULT

Your result

Enter your values and select Calculate.

Check the units and assumptions before using this result.

METHOD

How the solar panel calculator works

How to use this calculator

Enter measured values in the stated units and check which assumptions are fixed. Calculate, review the breakdown, then change one input for a consistent comparison.

What the result means

Peak-sun hours express an equivalent irradiation duration at a reference intensity. They are not the same as clock hours between sunrise and sunset. Calculator ForEver applies the same entered average to each selected day and scales output by one performance factor. The result can help check arithmetic or compare assumptions, but it does not retrieve weather, roof orientation, shading or an inverter performance curve.

The formula

Generated kWh = nameplate kW × peak-sun-hours/day × days × performance fraction

A worked example

5 kW × 4 peak-sun-hours × 30 days × 80% = 480 kWh.

Assumptions & methodology

Peak-sun-hours are equivalent full-power irradiance hours, not daylight hours. No site weather, shading, orientation, storage, degradation, tariff timing or self-consumption model. Valuing all generation at the entered tariff is an assumption, not bill savings. Results are rounded for display; intermediate calculations retain precision. This tool is informational and does not replace institutional or professional guidance.

References

NREL: PVWatts system modeling manual · PVWatts: interpreting energy-value results

WORK THROUGH THE DETAILS

Using your solar panel result

Inspect a change in sunlight independently

For the 5 kW, 80% example over 30 days, three peak-sun hours per day give 360 kWh, while five give 600 kWh. Capacity and the performance assumption stay fixed, so the difference follows from the chosen irradiation exposure. Real daily conditions do not normally stay identical through the month. A monthly average can be a useful input only when its definition matches the array conditions and the period you intend to represent.

Treat energy value as an entered-price illustration

At 480 kWh and an entered energy price of 0.20 per kWh, multiplying gives 96.00. That amount assumes each generated kWh carries the same value under the stated comparison. Actual bill savings can depend on self-consumption timing, export compensation, demand charges and tariff structure. Generated energy is not automatically equivalent to purchased energy avoided. The calculator does not decide whether a particular metering or export arrangement applies to your property.

Separate solar generation from battery storage

A battery can shift when some energy is used, but storage adds its own capacity, power and loss constraints. This solar estimate does not size a battery or guarantee backup hours during an outage. A 10 kWh battery also does not mean a 10 kW solar array. Use Battery Life for its limited constant-current charge-budget model and retain the appropriate voltage or energy model when discussing a real storage system.

Use a location model for an equipment decision

A production estimate for an actual installation needs solar resource data, mounting geometry, shading and system behavior. A dedicated model such as PVWatts includes inputs beyond this simple product. Do not present Calculator ForEver’s constant-factor estimate as a reproduction of that model or a production guarantee. Capital costs, incentives, financing, maintenance and degradation are also absent, so the result does not calculate payback or an investment return without a separate cash-flow analysis.

Use a shared period when comparing with consumption

An estimate of 480 kWh over 30 days should be compared with consumption over the same span. Comparing it with a 365-day demand value combines different time bases. Dividing either total by its number of days can make the period difference visible, but seasonal patterns may still differ.

INTERPRETATION

Understanding solar panel results

Keep capacity and energy units distinct

A 5 kW array rating describes power under its rating conditions. The kWh result describes accumulated energy over the chosen period. At four equivalent peak-sun hours, a 5 kW system has an unadjusted daily energy scenario of 20 kWh. Applying an 80% factor gives 16 kWh per day. An energy number without the selected number of days cannot be compared fairly with a monthly electricity bill or an annual production report.

Apply the performance factor once

Enter 80 for an 80% performance assumption, which multiplies the unadjusted result by 0.80. Do not enter a sunlight figure already reduced for the same modeled losses and then apply them again through the factor. The combined factor is a scenario input, not a measured equipment efficiency or a complete loss model. It can represent an aggregate allowance, but its justification needs information outside this multiplication.

RELATED GUIDES

Related questions and worked examples

Read a worked explanation before trying another calculation.

QUESTIONS

Solar Panel questions

Are peak-sun hours the hours of daylight?+

No. They represent an equivalent irradiation exposure at a reference intensity. Clock daylight duration alone does not describe the energy received by a particular array.

Does the value estimate include export tariffs or incentives?+

No. It multiplies generation by your entered price. Export rates, self-consumption, taxes, incentives and billing rules need a separate applicable model.