CalculatorForEver
MATH / CALCULATOR

Battery Life Calculator

Calculate battery life with stated units, an editable scenario and a worked result breakdown.

Battery runtime under a constant-current assumption is usable capacity divided by load current. A 2,000 mAh capacity, 100 mA load and 80% usable-capacity assumption give 2,000 × 0.80 / 100 = 16 hours. This is a charge-budget estimate rather than a battery discharge simulation.

Your numbers

BROWSER-LOCAL INPUTS

Your inputs stay in this browser. No account needed.

RESULT

Your result

Enter your values and select Calculate.

Check the units and assumptions before using this result.

METHOD

How the battery life calculator works

How to use this calculator

Enter measured values in the stated units and check which assumptions are fixed. Calculate, review the breakdown, then change one input for a consistent comparison.

What the result means

A capacity in milliamp-hours describes an amount of electric charge under specified test conditions. Dividing that capacity by milliamps produces hours when current stays constant. Calculator ForEver lets you apply a chosen usable percentage before the division. Real discharge can depend on chemistry, temperature, load pattern, age, voltage limits and the conditions used to rate the battery. The percentage is an assumption you supply, not a measured state of health.

The formula

Hours = capacity mAh × usable fraction / current mA

A worked example

2,000 mAh at 100 mA gives 20 ideal hours; 80% usable gives 16 hours.

Assumptions & methodology

Capacity and load current must be on the same battery-side basis. No Peukert effect, aging, temperature, cutoff-voltage or converter-efficiency curve. Rated mAh cannot be compared across voltages without an energy conversion. Results are rounded for display; intermediate calculations retain precision. This tool is informational and does not replace institutional or professional guidance.

References

EIA: measuring electricity and energy units · OpenStax: electric current and charge

WORK THROUGH THE DETAILS

Using your battery life result

Check a pulsed-load average carefully

Suppose an illustrative circuit draws 80 mA for half the time and 20 mA for the other half. Its time-weighted average is 50 mA. A 1,000 mAh usable charge budget divided by that average gives 20 hours. That arithmetic assumes the load pattern repeats and the usable capacity remains appropriate for it. A large brief peak can still exceed a cell or regulator limit even when the average is small. This form does not evaluate peak-current capability or voltage sag.

Keep series and parallel wiring outside the simple division

Combining cells changes voltage and charge capacity according to the arrangement and the behavior of the cells. A pack rating may already account for those connections. Enter the pack capacity applicable at the point where the current is measured rather than adding unlike ratings by intuition. For a regulated output, the load-side current can differ from battery current because voltage changes and conversion losses intervene. A Wh-based energy model can be more suitable for a constant-power load.

Recognize the constant-current boundary

A device may increase its input current as battery voltage falls while maintaining nearly constant power. Such operation violates the fixed-current assumption. The estimate also omits self-discharge, temperature changes, capacity fade and chemistry-specific rate effects, including Peukert-type behavior in relevant batteries. An observed runtime therefore need not match the ratio even when the label and entered current are correct. Use manufacturer discharge curves or a measured profile when the endpoint voltage and load behavior matter.

Use the result as a reproducible scenario

At 2,400 mAh, 60 mA and 100% usable, the arithmetic gives 40 hours. Changing only usable capacity to 70% gives 28 hours. Changing only current to 120 mA halves either result. Those comparisons show how the assumed charge budget and load affect the estimate; they do not prove that the battery delivers the chosen capacity. Record the pack rating, current measurement point and cutoff assumptions with a saved result before comparing devices.

INTERPRETATION

Understanding battery life results

Match milliamp-hours with milliamps

Capacity and current need matching prefixes. A load of 0.2 A equals 200 mA, so a 1,000 mAh usable capacity supplies that assumed load for five hours. Entering 0.2 into a field labeled mA would instead describe a load one thousand times smaller. Check whether a device specification states current, power or energy before entering it. Watts cannot replace milliamps without a voltage relationship and suitable conversion assumptions.

Treat usable capacity as a chosen allowance

If nominal capacity is 3,000 mAh and you select 75% usable, the model uses 2,250 mAh. At 150 mA, that gives 15 hours. The calculation does not explain why the missing 25% is unavailable. It might represent a planning reserve or an assumed reduction, but it is not a universal correction for a chemistry or age. Do not interpret a selected percentage as an independent battery test.

RELATED GUIDES

Related questions and worked examples

Read a worked explanation before trying another calculation.

QUESTIONS

Battery Life questions

Can a watt-hour rating go directly into the mAh field?+

No. Watt-hours describe energy and mAh describe charge. Relating them requires voltage and can require a conversion-efficiency model when a regulator changes the output voltage.

Does 100% usable mean the battery can safely be fully discharged?+

No. It only tells the arithmetic to use the entire entered rating. Permissible discharge limits depend on the battery, protection circuit and application.